Description
WEH® Filter TSF2 H₂ for installation in H2 fuelling stations, with external and internal thread, Filter 20 Micron, 350 bar
Contaminants in the gas flow can enter the vehicle‘s storage tank during refuelling. These dirt particles in the hydrogen fuel may cause damage to the sealing components. WEH, therefore, offers the WEH® TSF2 H2 Filter Series for clean hydrogen.Solid particles are captured reliably.The filter element can be removed and is re-usable after having been cleaned.
The WEH® TSF2 H2 Filter with external thread and internal thread is mainly used for fuelling stations and dispensers, for use as a prefilter in the WEH® TSA2 H2 Inline Breakaway Coupling.
Features
- For hydrogen free of impurities
- Filter insert can be cleaned
- Prefilter for inline breakaways
Technical Data
Nominal bore (DN) | 8 mm |
Pressure range | PN = 350 bar (5,000 psi) | PS = 450 bar | PT = 675 bar |
Temperature range | -40 °C up to +85 °C |
Media inlet | UNF 9/16"-18 external thread, SAE J514, 37° |
Material | Corrosion resistant stainless steel |
Sealing material | Hydrogen compatible |
Filter element | 20 micron |
Conformity / Tests / Approvals | PED 2014/68/EU |
Part No. | C1-134711 |
Application
Filter with external thread and internal thread for installation in H2 fuelling stations, for use as a prefilter in the TSA2 H2 Inline Breakaway Coupling.
Only use filters with EC79 approval for fitment in vehicles!
Only use filters with EC79 approval for fitment in vehicles!
Downloads